COD. PJ702C-LCD
Power: 700W
700W Compact amplifier.
Features
PRIMARY APPLICATION: uncompromised amplification power at a very attractive price. Ideal for small to medium power stations.
AMPLIFIER FEATURES: high-gain amplifier with very low input drive power requirement and adjustable power output from 10 to 100 %.
HARDWARE FEATURES: extremely compact and rugged thanks to the stainless steel chassis, in only 2HE.
USER-FRIENDLY FEATURES: four pushbuttons for user/device interaction and software that offers a simple, intuitive interface.
OPERATING EFFICIENCY: incorporate a PFC (Power Factor Corrector) power supply, that provides the utmost efficiency for enhanced energy saving and environmental protection, which added to LD-MOSFET technology ensure high efficiency, better than 70% across the bandwidth.
EASE OF MAINTENANCE: advanced module engineering ensures extreme ease of access and simple maintenance. Includes an high performance air filter. The power supply is plug-in type, easily removable.
RELIABILITY/CONTINUITY: APC (Automatic Power Control) and Foldback protection ensure reliable operation under any operating conditions.
INTERFACE CONTROL: total control thanks to microprocessor easily programmed from menu with all key parameters displayed on LCD.
REMOTE CONTROL: electromechanically controllable and integrable into all digital RVR telemetry systems.
REGULATORY COMPLIANCE: state-of-the-art technology in full compliance with EC, FCC and CCIR standards.
The image of this layout is purely demonstrative and may change without notice.
PRIMARY APPLICATION: uncompromised amplification power at a very attractive price. Ideal for small to medium power stations.
AMPLIFIER FEATURES: high-gain amplifier with very low input drive power requirement and adjustable power output from 10 to 100 %.
HARDWARE FEATURES: extremely compact and rugged thanks to the stainless steel chassis, in only 2HE.
USER-FRIENDLY FEATURES: four pushbuttons for user/device interaction and software that offers a simple, intuitive interface.
OPERATING EFFICIENCY: incorporate a PFC (Power Factor Corrector) power supply, that provides the utmost efficiency for enhanced energy saving and environmental protection, which added to LD-MOSFET technology ensure high efficiency, better than 70% across the bandwidth.
EASE OF MAINTENANCE: advanced module engineering ensures extreme ease of access and simple maintenance. Includes an high performance air filter. The power supply is plug-in type, easily removable.
RELIABILITY/CONTINUITY: APC (Automatic Power Control) and Foldback protection ensure reliable operation under any operating conditions.
INTERFACE CONTROL: total control thanks to microprocessor easily programmed from menu with all key parameters displayed on LCD.
REMOTE CONTROL: electromechanically controllable and integrable into all digital RVR telemetry systems.
REGULATORY COMPLIANCE: state-of-the-art technology in full compliance with EC, FCC and CCIR standards.
| PJ702C-LCD | ||||
| Parameters | Conditions | U.M. | Value | Notes |
| GENERALS | ||||
| Frequency range | MHz | 87,5 ÷ 108 | ||
| Rated output power | W | 700 | ||
| Spurious & harmonic suppression | dBc | <75 (80 typical) | Meets or exceeds all FCC and CCIR rules | |
| Working temperature | °C | -5 to +50 | ||
| Working humidity | % | 95 | Withoutcondensing | |
| Working altitude | mt | Up to 3000 * | * With adequate air evacuation system in site | |
| POWER REQUIREMENTS | ||||
| Power supply type | Monophase | |||
| AC Power input | AC Supply Voltage | VAC | 230 ±15% | Monophase |
| AC Apparent Power Consumption | VA | 1002 | ||
| Active Power Consumption | W | 1000 | ||
| Overall Efficiency | % | Typical 70 | ||
| Power factor | 0,998 | |||
| Connector | VDE IEC Standard | |||
| DC Power input | DC Supply Voltage | VDC | ||
| DC Current | ADC | |||
| MECHANICAL | ||||
| Phisical dimensions | Front panel width | mm / inch | 483 / 19 | EIA rack |
| Front panel height | mm / inch | 88 / 3 1/2 | ||
| Overall depth | mm | 390 | ||
| Chassis depth | mm | 370 | ||
| Weight | kg | About 10 | ||
| Cooling type | Forced, with internal fan | |||
| Power dissipated in heat | W | 300 | ||
| Acoustic noise | dBA | < 75 | Leq 3 min @ 1 m | |
| RF INPUT | ||||
| RF Input | Connector | N type | ||
| Impedance | Ohm | 50 | ||
| Driver power for rated output | W | 15 | ||
| Max input power before protection | W | 20 | ||
| RF OUTPUTS | ||||
| RF Output | Connector | N female type | ||
| Impedance | Ohm | 50 | ||
| RF Monitor | Connector | BNC | ||
| Impedance | Ohm | 50 | ||
| Output Level | dBc | Approx. -60 | ||
| AUXILIARY CONNECTIONS | ||||
| Interlock | Connector | 2 x BNC | For remote power inhibition (short is RF off) | |
| Service | Connector | DB9 F | Factory reserved for firmware program | |
| I²Cbus | Connector | DB9 F | ||
| Telemetry interface | Connector | DB25 F | ||
| FUSES | ||||
| On mains | 1 External fuse F 16 - 5 x 20 mm | |||
| On services | X | |||
| On PA Supply | X | |||
| On aux VDE Socket | X |