CERCA


ACCESSORI PER STAZIONI
Prodotti


HC2-5GRL

COD. HC2-5GRL

HC2-5GRL

Accoppiatore Ibrido 2VIE 5.000W.

HC2-5GRL
Parameters Conditions U.M. Value Notes
GENERALS
Frequency range
MHz 87,5 ÷ 108
Rated output power
W 5000 Continuously variable by software from 10 to 100%
Unbalaced power limit
W 1350
Working temperature
°C -5 to +50
Ambient working humidity
% 85 Without condensing
POWER REQUIREMENTS
AC Power input AC Supply Voltage VAC 117 ÷ 230 +10% -15% Internal switch

AC Apparent Power Consumption VA 61

Active Power Consumption  W 61

Power factor
0,998

Connector
VDE IEC Standard
DC Power input
DC Supply Voltage VDC

DC Current ADC

MECHANICAL DIMENSIONS
Phisical dimensions Front panel width mm / inch 483  /  19 EIA rack

Front panel height mm / inch 132  /  5 1/4     3HE

Overall depth mm 573

Chassis depth mm 501
Weight
kg About 16
Cooling type

Forced, with internal fan
Acoustic noise
dBA < 75
AUDIO INPUTS
Power Splitter Connector
N type

Impedance Ohm 50

Power W 150 0,1 dB step adjustable
Power Coupler Connector
7/8" EIA

Impdance Ohm 50

Number of way
2

Power W 2500 0,1 dB step adjustable
OUTPUTS 
Power Coupler Connector
7/8" EIA

Impedance Ohm 50
Power Splitter Connector
N-Type

Impedance Ohm 50

Number of Way
2
FUSES
On mains

1 External F 3,15 T - 5 x 20 mm
On services

X
On PA Supply

X
On driver supply

X


L’immagine di questo layout è puramente dimostrativo e può subire variazioni anche senza preavviso.








Scarica il Catalogo Generale

ISCRIVITI ALLA NOSTRA NEWSLETTER

Ricevi tutte le novità e le promozioni